{"product_id":"ecko-15kn-panel-hold-down-kit","title":"Ecko 15kN Panel Hold-Down Kit (10 Pack)","description":"\u003cp\u003eEcko 15kN Panel Hold-Down Kit (10 Pack)\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ex2 ECKO Brackets\u003c\/li\u003e\n\u003cli\u003ex2 M10 x 140mm Screw Bolts\u003c\/li\u003e\n\u003cli\u003ex10 14g x 35mm Hex Head Screws\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eECKO Bracing Bracket has been developed and tested in NZ to be installed with commonly used bracing systems where\u003cbr\u003ehold-downs are required at both ends of the bracing element. The system was tested by BRANZ (ST-18221) under the\u003cbr\u003eEM1 methodology specified in NZS3604:2011.\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecified by\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg sizes=\"(max-width: 300px) 100vw, 300px\" srcset=\"https:\/\/www.ecko.co.nz\/wp-content\/uploads\/RRHEE-logo-200x49.png 200w, https:\/\/www.ecko.co.nz\/wp-content\/uploads\/RRHEE-logo-300x73.png 300w, https:\/\/www.ecko.co.nz\/wp-content\/uploads\/RRHEE-logo-400x97.png 400w, https:\/\/www.ecko.co.nz\/wp-content\/uploads\/RRHEE-logo.png 494w\" height=\"73\" width=\"300\" alt=\"\" src=\"https:\/\/www.ecko.co.nz\/wp-content\/uploads\/RRHEE-logo-300x73.png\" class=\"alignnone wp-image-5220 size-medium\" decoding=\"async\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg sizes=\"(max-width: 1024px) 100vw, 1024px\" srcset=\"https:\/\/www.ecko.co.nz\/wp-content\/uploads\/Screenshot-2025-05-19-at-4.09.25 PM-200x72.png 200w, https:\/\/www.ecko.co.nz\/wp-content\/uploads\/Screenshot-2025-05-19-at-4.09.25 PM-300x108.png 300w, https:\/\/www.ecko.co.nz\/wp-content\/uploads\/Screenshot-2025-05-19-at-4.09.25 PM-400x144.png 400w, https:\/\/www.ecko.co.nz\/wp-content\/uploads\/Screenshot-2025-05-19-at-4.09.25 PM-500x180.png 500w, https:\/\/www.ecko.co.nz\/wp-content\/uploads\/Screenshot-2025-05-19-at-4.09.25 PM-600x216.png 600w, https:\/\/www.ecko.co.nz\/wp-content\/uploads\/Screenshot-2025-05-19-at-4.09.25 PM-700x253.png 700w, https:\/\/www.ecko.co.nz\/wp-content\/uploads\/Screenshot-2025-05-19-at-4.09.25 PM-768x277.png 768w, https:\/\/www.ecko.co.nz\/wp-content\/uploads\/Screenshot-2025-05-19-at-4.09.25 PM-800x289.png 800w, https:\/\/www.ecko.co.nz\/wp-content\/uploads\/Screenshot-2025-05-19-at-4.09.25 PM-1024x369.png 1024w, https:\/\/www.ecko.co.nz\/wp-content\/uploads\/Screenshot-2025-05-19-at-4.09.25 PM.png 1189w\" height=\"369\" width=\"1024\" alt=\"\" src=\"https:\/\/www.ecko.co.nz\/wp-content\/uploads\/Screenshot-2025-05-19-at-4.09.25%E2%80%AFPM-1024x369.png\" class=\"alignnone wp-image-5214 size-large\" decoding=\"async\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConcrete Floor – Internal Wall\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAt both ends of the bracing element, the bottom plate is fixed using a ECKO’s 15kN screw bolt. The bracket should be placed in the center of the bottom plate and all 5 screws be installed through the top flange into the corresponding stud.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConcrete Floor – External Wall\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAt both ends of the bracing element, the bottom plate is fixed using a ECKO’s 15kN screw bolt. The bracket should be aligned with the inside edge of the bottom plate to maximise edge distance. All 5 screws be installed through the top flange into the corresponding stud.\u003c\/p\u003e\n\u003cp\u003e\u003cimg sizes=\"(max-width: 1024px) 100vw, 1024px\" srcset=\"https:\/\/www.ecko.co.nz\/wp-content\/uploads\/Screenshot-2025-05-19-at-4.16.04 PM-200x70.png 200w, https:\/\/www.ecko.co.nz\/wp-content\/uploads\/Screenshot-2025-05-19-at-4.16.04 PM-300x105.png 300w, https:\/\/www.ecko.co.nz\/wp-content\/uploads\/Screenshot-2025-05-19-at-4.16.04 PM-400x140.png 400w, https:\/\/www.ecko.co.nz\/wp-content\/uploads\/Screenshot-2025-05-19-at-4.16.04 PM-500x175.png 500w, https:\/\/www.ecko.co.nz\/wp-content\/uploads\/Screenshot-2025-05-19-at-4.16.04 PM-600x210.png 600w, https:\/\/www.ecko.co.nz\/wp-content\/uploads\/Screenshot-2025-05-19-at-4.16.04 PM-700x245.png 700w, https:\/\/www.ecko.co.nz\/wp-content\/uploads\/Screenshot-2025-05-19-at-4.16.04 PM-768x268.png 768w, https:\/\/www.ecko.co.nz\/wp-content\/uploads\/Screenshot-2025-05-19-at-4.16.04 PM-800x279.png 800w, https:\/\/www.ecko.co.nz\/wp-content\/uploads\/Screenshot-2025-05-19-at-4.16.04 PM-1024x358.png 1024w, https:\/\/www.ecko.co.nz\/wp-content\/uploads\/Screenshot-2025-05-19-at-4.16.04 PM-1200x419.png 1200w, https:\/\/www.ecko.co.nz\/wp-content\/uploads\/Screenshot-2025-05-19-at-4.16.04 PM.png 1231w\" height=\"358\" width=\"1024\" alt=\"\" src=\"https:\/\/www.ecko.co.nz\/wp-content\/uploads\/Screenshot-2025-05-19-at-4.16.04%E2%80%AFPM-1024x358.png\" class=\"alignnone size-large wp-image-5217\" decoding=\"async\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStep 1\u003c\/strong\u003e\u003cbr\u003eUsing the correct masonry drill bit,\u003cbr\u003edrill a hole to the required embedment\u003cbr\u003e+10mm. Ensure that the minimum edge\u003cbr\u003edistance of 55mm is adhered too.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStep 2\u003c\/strong\u003e\u003cbr\u003eClean dust and debris from hole.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStep 3\u003c\/strong\u003e\u003cbr\u003ePut the bracket in place and screw in\u003cbr\u003eanchor using torque wrench or impact\u003cbr\u003ewrench until flange head is firmly secured\u003cbr\u003eagainst the bracket. DO NOT OVER-\u003cbr\u003eTIGHTEN. Install all 5 screws in top flange.\u003c\/p\u003e\n\u003ch3 class=\"fusion-responsive-typography-calculated\" data-lineheight=\"24px\" data-fontsize=\"16\"\u003e\u003cstrong\u003eHotEdge\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe ECKO M10 x 155 Screw Bolt (Orange Head) was developed in partnership with Firth to provide a fixing for a 90mm bottom plate where Firth’s RibRaft HotEdge Extra insulation is used and can be substituted for the blue headed screw bolt provided. The Orange head screw bolt has been BRANZ tested (ST18050-01-02) and meets the required 15kN pullout rating to be used in common bracing systems, along with 3kN out of plane and 2kN in plane requirements set out in NZ3604:2011.\u003c\/p\u003e\n\u003cp\u003e\u003cimg sizes=\"(max-width: 1024px) 100vw, 1024px\" srcset=\"https:\/\/www.ecko.co.nz\/wp-content\/uploads\/Screenshot-2025-05-19-at-4.02.02 PM-200x70.png 200w, https:\/\/www.ecko.co.nz\/wp-content\/uploads\/Screenshot-2025-05-19-at-4.02.02 PM-300x104.png 300w, https:\/\/www.ecko.co.nz\/wp-content\/uploads\/Screenshot-2025-05-19-at-4.02.02 PM-400x139.png 400w, https:\/\/www.ecko.co.nz\/wp-content\/uploads\/Screenshot-2025-05-19-at-4.02.02 PM-500x174.png 500w, https:\/\/www.ecko.co.nz\/wp-content\/uploads\/Screenshot-2025-05-19-at-4.02.02 PM-600x209.png 600w, https:\/\/www.ecko.co.nz\/wp-content\/uploads\/Screenshot-2025-05-19-at-4.02.02 PM-700x243.png 700w, https:\/\/www.ecko.co.nz\/wp-content\/uploads\/Screenshot-2025-05-19-at-4.02.02 PM-768x267.png 768w, https:\/\/www.ecko.co.nz\/wp-content\/uploads\/Screenshot-2025-05-19-at-4.02.02 PM-800x278.png 800w, https:\/\/www.ecko.co.nz\/wp-content\/uploads\/Screenshot-2025-05-19-at-4.02.02 PM-1024x356.png 1024w, https:\/\/www.ecko.co.nz\/wp-content\/uploads\/Screenshot-2025-05-19-at-4.02.02 PM.png 1151w\" height=\"356\" width=\"1024\" alt=\"\" src=\"https:\/\/www.ecko.co.nz\/wp-content\/uploads\/Screenshot-2025-05-19-at-4.02.02%E2%80%AFPM-1024x356.png\" class=\"alignnone wp-image-5213 size-large\" decoding=\"async\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStep 1\u003c\/strong\u003e\u003cbr\u003eUsing a 10mm masonry drill bit, drill a\u003cbr\u003ehole to the required embedment +\u003cbr\u003e10mm. Ensure that the minimum edge\u003cbr\u003edistance (from outside of insulation) of\u003cbr\u003e58mm is adhered too.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStep 2\u003c\/strong\u003e\u003cbr\u003eClean dust and debris from hole.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStep 3\u003c\/strong\u003e\u003cbr\u003ePut the bracket in place and screw in\u003cbr\u003eanchor using torque wrench or impact\u003cbr\u003ewrench until flange head is firmly secured\u003cbr\u003eagainst the bracket. DO NOT OVER-\u003cbr\u003eTIGHTEN. Install all 5 screws in top flange.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e* 15kN hold down is dependent on a minimum of 20MPa concrete.\u003cbr\u003e** Two additional holes are provided on the bottom flange to allow specific engineered design for alternative fixings (ie balustrade fixing, post fire stability, etc)\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Ecko","offers":[{"title":"Default Title","offer_id":53147438678176,"sku":"MBB-KIT","price":106.59,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0258\/9655\/0472\/files\/Bracket-Kit-Bag.png?v=1767686705","url":"https:\/\/nzfasteners.co.nz\/products\/ecko-15kn-panel-hold-down-kit","provider":"NZ Fasteners","version":"1.0","type":"link"}